DIGITAL LINK MEASURING INSTRUMENTS
2
Bit rate 1.544, 2.048, 34.368, 44.736, 139.264, 51.84, 155.52, 622.08 Mbit/s
Mapping
Traffic pattern CBR, burst, sawtooth, CBR/PCR with CDV, Poisson
Cell: Single cell PRBS 9, cross cell PRBS 9/15/23, 16-bit word pattern, edit pattern, time stamp
O.191: Edit pattern
AAL1: Single cell PRBS 9, cross cell PRBS 9/15/23, 16-bit word pattern, edit pattern, time stamp
Test patterns
AAL2 (CPS-PDU): Time stamp
AAL2 (CPS-PACKET): Single cell PRBS 7, 8-bit word pattern, edit pattern
AAL3/4 (SAR-PDU): Time stamp
AAL3/4 (CPCS-PDU): Single cell PRBS 9, cross cell PRBS 9/15/23, 16-bit word pattern, edit pattern
AAL5: Single cell PRBS 9, cross cell PRBS 9/15/23, 16-bit word pattern, edit pattern
Cell: HEC, programmable pattern
O.191: Lost cell, misinserted cell, errored cell, SECB
AAL1: Lost cell, SNP, PRBS, word
Error addition
AAL2 (CPS-PDU): P, SN, OSF
AAL2 (CPS-PACKET): HEC, PRBS, word
AAL3/4 (SAR-PDU): SN, CRC10, segment type, LI, abort
AAL3/4 (CPCS-PDU): CPI, B/E tag mismatch, BA size, AL, length, PRBS, word
AAL5: Frame size, length, CRC32, abort, PRBS, word
Alarm addition LCD, VP/VC AIS, VP/VC RDI, VP/VC CC, VP/VC loopback cell
PM cell Error insertion: Lost cell, misinserted cell, BIPV, SECB
Cell editing O.191, AAL1, AAL2, AAL3/4, AAL5, AIS, RDI, CC, loopback, FM, BR, background (10 ch)
Memorized cell Possible to send after editing receiver's capture data
Mode: Single, repeat, manual
Error
Cell: Cell count, correctable HEC, uncorrectable HEC, non-conforming cell
O.191: Errored cell, lost cell, misinserted cell, SECB
AAL1: SAR-PDU count, lost cell, SNP, uncorrectable SNP, PRBS, word
AAL2: CPS-PDU count, P, OSF, SN, CPS packet count, CID count, HEC, PRBS, word
AAL3/4
: SAR-PDU count, CRC10, MID count (SAR-PDU with selected MID value), SN, ST (segment type), LI, abort, discarded
PDU (one of SN error, Ll error, abort, COM with ST error, or EOM with ST error), CPCS-PDU count, CPI, B/E tag
Measurement mismatch, BA size, AL, length, undeliverded PDU (one of CPI error, B/E tag mismatch, BA size error, AL error, or
length error), PRBS, word
CRC10 is calculated for all SAR-PDU. The others are calculated for SAR-PDU with specified MID.
AAL5: CPCS-PDU count, frame size, length, CRC32, abort, discarded PDU (one of frame size error, length error, CRC32 error,
or abort), PRBS, word
FM: Lost cell, misinserted cell, BIPV, SECB
BR: Lost cell, misinserted cell, BIPV, SECB
Alarm: LCD, VP/VC segment AIS, VP/VC end-to-end AIS, VP/VC segment RDI, VP/VC end-to-end RDI, VP/VC segment LOC,
VP/VC end-to-end LOC
LED LCD, VP-AIS, VP-RDI, VP-LOC, VC-AIS, VC-RDI, VC-LOC, errors
Monitor Live monitor (1023 channel monitor), traffic monitor, cell monitor
Delay measurement 1-point CDV, 2-point CDV
Capture 1 to 2016 cells
Wander measurement is valid when MU150005A/150006A/150007A Option 02 is mounted. Conforms to ITU-T O.172
Reference input: 2.048M (HDB3, clock), 1.544M (AMI/B8ZS, clock), 64k + 8 kHz, 5 MHz, 10 MHz
Sampling frequency: 320 Hz, 40 Hz, 1 Hz, 0.1 Hz, 5 mHz (select from MX150001B)
Measurement range
P-P: 0.0 to 2E10 ns, +P/P: 0.0 to 1E10 ns, TIE: 0.0 to ±1E10 ns
Accuracy: Conform to ITU-T O.172
Measurement time: 10 to 1 x 10
8
s (Max. 120,000 s: MP1570A only)
Wander application (requires MX150001B Wander Application Software)
Wander measurement
TIE: Max. 1 x 10
8
s
MTIE: Max. 1 x 10
8
s
TDEV: Max. 1 x 10
6
s
Frequency offset: Measurement with conform to ANSI TI.105.09
Frequency drift rate: Measurement with conform to ANSI TI.105.09
MRTIE: Evaluation separated from the wander by the frequency variation
Wander tolerance (TDEV) measurement: Evaluation by the various TDEV mask generations
Wander transfer (TDEV) measurement: Calibration method by simulation, outputting results by the one measurement
MP0123A ATM Unit
SDH /SONET
PDH /DSn
AAL1
ATM/AAL
AAL2
AAL3/4
AAL5
ATM
STM-1c /STS-3c
STM-0 /STS-1
139M (G.832)
34M (G.832)
2M (G.704)
45M (G.704)
1.5M (G.704)
STM-4c /OC-12c (optical)
STM-1c /OC-3c (optical)