DIGITAL LINK MEASURING INSTRUMENTS
162 For product ordering information, see pages 4 –10
Conforms to ITU-T O.172
LP, HP0 + LP, HP1 + LP, HP2 + LP, HP + LP
Accuracy (UIp-p, UI+p, UI–p)
2 UI range: Measurement value ±R% ±W UIp-p, 32 UI range: Measurement value ±R% ±W UIp-p
[MU150008A/150009A/150010A are simultaneously installed, conform to ITU-T O.172]
Fixed error [W]
Input level: –12 to –10 dBm (adds to 0.01 UIp-p/dB at <–12 dBm)
Jitter measurement
Accuracy (UIrms)
2 UI range: ±R% ±Y UIrms, 32 UI range: ±R% ±Y UIrms
Fixed error [Y]
Input level: –12 to –10 dBm (adds to 0.002 UIrms/dB at <–12 dBm)
Frequency error [R]
Hit measurement Count, Seconds, % free seconds
Frequency measurement
Resolution: 0.1 ppm, Display: Hz or ppm (after power-on, calibrates after 60 min warm-up, 23˚ ±5˚C)
Auxiliary interface Reference clock input
Jitter tolerance measurement: Evaluates jitter tolerance point automatically
Jitter sweep measurement: Conforms to high-speed jitter tolerance evaluation for mass production, etc.
Auto jitter measurement
Jitter transfer measurement: High dynamic range measurement by selective level method
Frequency sweep measurement: Measures the jitter tolerance automatically while changing the offset
Modulation frequency: 10 µHz to 0.2 Hz (sine wave)
Amplitude: 0 to 57,600 UIp-p (30 UIp-p steps)
Line wander generation
Accuracy: ±Q% ±160 UIp-p
Auto wander measurement
Wander sweep measurement
Reference wander generation is valid when MU150005A/150006A/150007A Option 03 is mounted.
Off: Able to set non-modulated status
Reference wander
TDEV mask:
generation
The 37 types of TDEV masks that are regulated by ITU-T, ETSI, ANSI, and Bellcore standards are available as default.
It is possible to add the wander modulation to the user specified TDEV mask.
Transient: It is possible to change the A (1 – e
–63.7t
) phase by the timing of the start.
Signal off: It is possible to disconnect the standard signal.
At PRBS 2
23
– 1
Bit rate
SONET/SDH signal
(Mbit/s)
HP1 + LP HP2 + LP
2 UI 32 UI 2 UI 32 UI
Container
2488.32 0.100 2.2 0.050 1.40 VC4-16c
At PRBS 2
23
– 1
Bit rate
SONET/SDH signal Clock signal
(Mbit/s)
HP + LP
Container
HP + LP
2 UI 32 UI 2 UI 32 UI
2488.32 0.012 0.08
VC4-16c
0.010 0.16
Bit rate
Clock signal
(Mbit/s)
HP1 + LP HP2 + LP
2 UI 32 UI 2 UI 32 UI
2488.32 0.050 0.60 0.030 0.50
Frequency error Frequency range
±7% 5 to 300 kHz
±8% 300 kHz to 1 MHz
±10% 1 to 3 MHz
±15% 3 to 10 MHz
±20% 10 to 20 MHz
Frequency error Frequency range
±8% 10 µHz to 0.1 Hz
±12% 0.1 to 0.2 Hz