Procedure
Step 1. Reset the Site Master to the factory default settings if a known starting state is
desired.
If the unit is off, hold down the ESC/CLEAR key while pressing the ON/OFF
key.
If the unit is already on, press the RECALL SETUP key on the data keypad.
When the key is pressed, a Recall Trace selection box appears on the display.
Select setup location 0 to recall the factory preset state.
Step 2. Using the test port extension cable and 30 dB attenuator, connect the signal
source to the input of the attenuator, and connect the output of the attenuator to
the
RF In test port of the Site Master.
Step 3.
Press the AMPLITUDE key and select the
REF LEVEL soft key to set the refer-
ence level to 0 dBm.
Step 4. Press the
SCALE soft key and set the scale to 10 dB/division.
Step 5. Press the
ATTEN soft key followed by the MANUAL soft key and set the attenua-
tion to 20 dB.
Step 6.
Press the SWEEP key and select the
RBW and VBW soft keys to set the resolu-
tion bandwidth to 1 MHz and the video bandwidth to AUTO.
Step 7. Press the
MAX HOLD soft key to set max hold to ON as indicated in the lower
left of the display.
Step 8. Press the
MEASURE soft key and press the CHANNEL POWER soft key.
Step 9. Select the
CENTER FREQ soft key and set the center frequency of the GSM sig-
nal to 947.5 MHz.
Step 10. Select the
INT BW soft key and enter 2.0 MHz for the integration bandwidth, or
set the integration bandwidth appropriate for the particular application.
Step 11. Select the
CHANNEL SPAN soft key and enter 4.0 MHz as the channel span, or
set the channel span to a value appropriate for the particular application.
Step 12. Make the measurement by pressing the
MEASURE ON/OFF soft key. The detec-
tion method is automatically changed to Average. Solid vertical lines are drawn
on the display to indicate the integration bandwidth. The Site Master will dis-
play the measurement results.
5-13
Chapter 5 Spectrum Analyzer Measurements