95) Channel Selection (lower byte)
96) Frequency Scale Factor
201
(higher byte)
97) Frequency Scale Factor (lower byte)
98) Frequency Range Minimum
202
(highest byte)
99) Frequency Range Minimum
100) Frequency Range Minimum
101) Frequency Range Minimum (lowest byte)
102) Frequency Range Maximum
203
(highest byte)
103) Frequency Range Maximum
104) Frequency Range Maximum
105) Frequency Range Maximum (lowest byte)
106 – 150) Not Used
151) Power Meter Reading
204
(highest byte)
152) Power Meter Reading
153) Power Meter Reading
154) Power Meter Reading (lowest byte)
For T1 Tester / E1 Tester Mode (Option 50):
57) Receive Input (00h: Terminate, 01h: Bridged, 02h: Monitor)
58) Framing Mode
205
59) Line Coding (01h: B8ZS, 02h: AMI, 03h: HDB3)
60) Tx Level (Valid for T1 Only) (01h: 0 dB, 02h: -7.5 dB, 03h: -15 dB)
61) Clock Source (00h: External, 01h: Internal)
62) Error Insert Type (00h: Frame Error, 01h: BPV, 02h: Bit Errors, 04h: RAI, 05h: AIS)
63) Loop Code (Valid for T1 Only) (00h: CSU, 01h: NIU, 02h: User 1, 03h: User 2)
64) Loop Type (Valid for T1 Only) (00h: In Band, 01h: Data Link)
65) CRC Method (Valid for T1 Only) (00h: ANSI CRC, 01h: Japanese CRC)
66) Display Type (00h: Histogram, 01h: Raw Data)
67) Impedance (Valid for E1 Only) (01h: 75W, 02h: 120W)
68) Pattern
206
69) Pattern Invert Status (00h: Non-Inverted, 01h: Inverted)
70) Insert Bit Error Value (1-1000) (higher byte)
71) Insert Bit Error Value (lower byte)
72) Insert BPV Error Value (1-1000) (higher byte)
73) Insert BPV Error Value (lower byte)
74) Insert Frame Error Value (1-1000) (higher byte)
75) Insert Frame Error Value (lower byte)
76) Measurement Duration
207
77) Histogram Resolution
208
78) Frame Sync Status (00h: In Sync, 01h: Out-of-Sync)
Site Master PM 59
201 In number of Hz
202 Scaled by Frequency Scale Factor (bytes 96-97)
203 Scaled by Frequency Scale Factor (bytes 96-97)
204 Power sent as (power in dBm * 1000). Use two’s-complement method to decode negative power levels.
205 T1 Mode: 01h: ESF, 02h: D4SF
E1 Mode: 03h: PCM30, 04h: PCM30CRC, 05h: PCM31, 06h: PCM31CRC
206 Pattern: 01h: PRBS-9, 02h: PRBS-11, 03h: PRBS-15, 04h: PRBS-20(O.151), 05h: PRBS-20(O.153), 06h: PRBS-23,
07h: QRSS, 08h: 1 in 8, 09h: 2 in 8, 0Ah: 3 in 8, 0Bh: All Ones, 0Ch: All Zeros, 0Dh: T1-DALY, 0Eh: User Defined
207 Measurement Duration: 00h: Manual, 01h: 3 min, 02h: 15 min, 03h: 30 min, 04h: 1 hr, 05h: 3 hrs, 06h: 6 hrs, 07h: 12
hrs, 08h: 1 day, 09h: 2 days
208 Histogram Resolution: 00h: Auto, 01h: 1 sec, 02h: 15 sec, 03h: 30 sec, 04h: 45 sec, 05h: 1 min, 06h: 15 min, 07h: 30
min, 08h: 45 min, 09h: 60 min